Check Safty Sensors- Footrest 'top' side sensor - with the lift ascending, push top-side
spring-loaded edge of footrest - lift should stop immediately.
- Footrest 'bottom' side sensor - with the lift descending, push bottom-side
spring-loaded edge of footrest - lift should stop immediately.
- Footrest base sensor - with the lift descending, push the base of
the footrest upwards - lift should stop immediately.
- Carriage 'top' side sensor - with the lift ascending, push the top-side
spring-loaded molding attached to the carriage, immediately surrounding
the rail - lift should stop immediately.
- Carriage 'bottom' side sensor - with the lift descending, push the
bottom-side spring-loaded molding attached to the carriage immediately
above the rail - lift should stop immediately.
Check Stopping Limits- Bottom stopping limit operative - run the lift right to the bottom
of the rail - lift should automatically come to a 'soft' stop at the
foot of the staircase.
- Top stopping limit operative - run the lift right to the top of the
rail - lift should automatically come to a 'soft' stop at the top of
the staircase.
Check Remote Controls- Remote controls operative - pressing the red button causes the lift
to ascend after a 3 second delay - pressing the green button causes
the lift to descend after a 3 second delay.
Check Key Switch- Key 'off' LED warning - with the key in the 'stop' position, the red
LED is illuminated and the lift will not operate.
Check Seat Swivel Cut-out- Seat swivel LED warning - with the seat swivel mechanism not locked
in the riding position (i.e. facing up the staircase) the yellow LED
is illuminated and the lift will not operate.
Check Off-Charge Warning- Lift 'off-charge' audible warning - with the lift stopped in mid-travel,
(i.e. off the upper or lower charge points) a 40 second pause is followed
by the red, yellow and green LEDs flashing for 40 seconds accompanied
by an audible warning (continuous 'bleeping') for a further 40 seconds,
followed by restoration of a steady green LED - the lift will operate
as normal if activated by the toggle switch or remote controls.
|